HGY-1850 D6 LTP
2324 kVA StandBy Generator set Open Skid
Powered by: YANMAR
Alternator: MECC ALTE
Three phase | 60 Hz | Diesel |
- Engine Specifications 1.800 r.p.m.
- Rated Engine Output: 0kW cop ; 0kW prp ; 1975kW standby
- Manufacturer: YANMAR
- Model: 12GY175L.LF5S
- Engine Type: 4-stroke diesel
- Injection Type: Direct
- Aspiration Type: Turbocharged and after-cooled
- Number of cylinders and arrangement: 12-V
- Bore and Stroke: 175 x 215 mm
- Displacement: 62,1 L
- Cooling System: Water
- Lube Oil Specifications: SAE 15W-40, API CI-4 o CK-4
- Fuel Consumption 100% PRP: 449,08 l/h
- Fuel Consumption 75 % PRP: 349,15 l/h
- Fuel Consumption 50 % PRP: 251,58 l/h
- Fuel Consumption 25 % PRP: 149,30 l/h
- Lube oil consumption with full load: 0,4
- Total oil capacity: 306 L
- Governor Type Electrical
- Air Filter Type Dry
- Oil temperature sensor
- Low coolant level sensor
- Exhaust gas compensator
- Diesel engine
- 4-stroke cycle
- Water-cooled
- 24V electrical system
- Standard air filter
- Standard fuel filter
- Standard oil filter
- Radiator with pusher fan
- Radiator water level sensor
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Water separator filter (visible level) (Optional)
- Generator: MECC ALTE
- Model: ECO46.1L4A
- Poles: 4
- Connection type (standard): Star - Parallel
- Mounting type: S-00 21"
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Double drive-shaft
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - OPEN SET VERSION.
- Steel chassis
- Emergency stop button
- Oil sump extraction kit
- Anti-vibration shock absorbers
- Chassis with integrated fuel tank
- Fuel level gauge
- Manual oil drain pump
- High mechanical strength
- Fuel tank drain plug
- Steel industrial silencer -15db(A) attenuation (Optional)
- Steel residential silencer -35db(A) attenuation. (Optional)
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Connection panel wired to the safety protection (open thermal magnetic protection and alarm)
- Maintenance-free and anti-explosion battery
- Battery Switch
- Control panel and emergency stop button
- Battery charger (standard on gensets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- Heating resistor (standard on sets with automatic control panels) (Optional)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 480 ºC
- Exhaust Gas Flow: 363 m3/min
- Maximum allowed back pressure: 6 kPa
- - NECESSARY AMOUNT OF AIR.
- Alternator fan air flow: 2,7 m3/s
- - STARTING SYSTEM.
- Starting power: 9 x 2 kW
- Starting power: 12,24 x 2 CV
- - FUEL SYSTEM
- Fuel Oil Specifications: Diesel
- Fuel Tank: 450 L
- - DIMENSIONS.
- Length: 7.310 mm
- Height: 2.720 mm
- Width: 2.350 mm
- Maximum shipping volume: 46,73 m3
- Fuel tank capacity: 450 L
- Autonomy: 1 Hours
Power
kVA
0
2324
Prime power (6 - 2601)
Stand by (6.5 - 2627)
Stand by (6.5 - 2627)
kW
0
1859
Prime power (5.8 - 2081)
Stand by (6.2 - 2093)
Stand by (6.2 - 2093)
Sound level
dB
Distance (m)
Distance (m)
dimensions
Long (A)
731
Width (B)
235
High (C)
272
Long (A)
287,80
Width (B)
92,52
High (C)
107,09
Weight
Weight with liquid in radiator and carter
0 0
0 0
Fuel capacity
450
118,80