HDW-200 T5
199 kVA Generator set Open Skid
Powered by: HYUNDAI
Alternator: MECC ALTE
Three phase | 50 Hz | Diesel | Stage 2
- Engine Specifications 1.500 r.p.m.
- Rated Engine Output: 172kW prp ; 194kW standby
- Manufacturer: HYUNDAI
- Model: P086TI
- Engine Type: 4-stroke diesel
- Injection Type: Direct
- Aspiration Type: Turbocharged and after-cooled
- Number of cylinders and arrangement: 6-L
- Bore and Stroke: 111 x 139 mm
- Displacement: 8,071 L
- Cooling System: Coolant
- Lube Oil Specifications: API CH4 SAE 15W40 or 10W40
- Compression Ratio: 16,4:1
- Fuel Consumption ESP: 48,4 l/h
- Fuel Consumption 100% PRP: 43,1 l/h
- Fuel Consumption 75 % PRP: 31,7 l/h
- Fuel Consumption 50 % PRP: 21,1 l/h
- Fuel Consumption 25 % PRP: 11,3 l/h
- Lube oil consumption with full load: 0,5 % of fuel consumption
- Total oil capacity: 15,5 L
- Total coolant capacity: 44 L
- Governor Type Electrical
- Air Filter Type Dry
- Inner diameter exhaust pipe: 75 mm
- Diesel engine
- 4-stroke cycle
- Water-cooled
- 24V electrical system
- Water separator filter (no visible level)
- Dry air filter
- Radiator with pusher fan
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Generator: MECC ALTE
- Model: ECO38.2S4C
- Poles: 4
- Connection type (standard): Star-series
- Mounting type: S-1 14"
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - OPEN SET VERSION.
- Steel chassis
- Emergency stop button
- Anti-vibration shock absorbers
- Chassis with integrated fuel tank
- Fuel level gauge
- Fuel tank drain plug
- Steel industrial silencer -15db(A) attenuation
- Fuel transfer pump (Optional)
- Steel residential silencer -35db(A) attenuation. (Optional)
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- Battery Switch (Optional)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 580 ºC
- Exhaust Gas Flow: 33,9 m3/min
- Maximum allowed back pressure: 5,9 kPa
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 1017 m3/h
- Cooling Air Flow: 3,17 m3/s
- Alternator fan air flow: 0,533 m3/s
- - STARTING SYSTEM.
- Starting power: 6 kW
- Starting power: 8,16 CV
- Recommended battery: 100 Ah
- Auxiliary Voltage: 24 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: Diesel
- Maximum power suction pump: 75 mm Hg
- Maximum return feed pump: 450 mm Hg
- Fuel Tank: 449 L
- - DIMENSIONS.
- Length: 3.000 mm
- Height: 1.725 mm
- Width: 1.160 mm
- Maximum shipping volume: 6 m3
- Weight with liquids in radiator and sump: 1.990 kg
- Fuel tank capacity: 449 L
- Autonomy: 14 Hours
Power
kVA
199
220
Prime power (199 - 1034)
Stand by (220 - 1145)
Stand by (220 - 1145)
kW
159
176
Prime power (159 - 827)
Stand by (176 - 916)
Stand by (176 - 916)
Sound level
dB
Distance (m)
Distance (m)
dimensions
Long (A)
300
Width (B)
116
High (C)
172,50
Long (A)
118,11
Width (B)
45,67
High (C)
67,91
Weight
Weight with liquid in radiator and carter
1.990 4.387,95
1.990 4.387,95
Fuel capacity
449
118,54