HGS-1030 T6 BIO

 

HGS-1030 T6 BIO

1033 kVA COP Generator set Open Skid

Powered by: SIEMENS
Alternator: STAMFORD

 

Three phase | 60 Hz | Biogas |

 

 

  • Engine Specifications 1.800 r.p.m.
  • Rated Engine Output: 1067kW cop
  • Manufacturer: SIEMENS
  • Model: SGE56SL
  • Engine Type: 4-stroke Otto Cycle
  • Injection Type: Carburization
  • Aspiration Type: Turbocharged
  • Number of cylinders and arrangement: 16-V
  • Bore and Stroke: 160 x 175 mm
  • Displacement: 56,3 L
  • Cooling System: Water + Antifreeze
  • Lube Oil Specifications: SAE 40
  • Compression Ratio: 12,3
  • Fuel Consumption 100% PRP: 2842 kW
  • Fuel Consumption 80 % PRP: 2333 kW
  • Fuel Consumption 75 % PRP: 2224,37 kW
  • Fuel Consumption 50 % PRP: 1587,93 kW
  • Fuel Consumption 25 % PRP: 985,64 kW
  • Lube oil consumption with full load: 0,2
  • Total oil capacity: 272 L
  • Governor Type Electrical
  • Air Filter Type Semi-humid
  • Biogas Engine
  • 4-stroke cycle
  • Water-cooled
  • Radiator with pusher fan
  • HTW sender
  • LOP sender
  • Hot parts protection
  • Moving parts protection
  • Generator: STAMFORD
  • Model: HCI634K
  • Poles: 4
  • Connection type (standard): Star-series
  • Mounting type: S-00 18"
  • Insulation: H class
  • Enclosure (according IEC-34-5): IP23
  • Exciter system: Self-excited, brushless
  • Voltage regulator: A.V.R. (Electronic)
  • Bracket type: Double drive-shaft
  • Coupling system: Elastic Coupling
  • Coating type: Standard (Vacuum impregnation)
  • - OPEN SET VERSION.
  • Emergency stop button
  • Steel chassis
  • Steel industrial silencer -15db(A) attenuation
  • Steel residential silencer -35db(A) attenuation.
  • - GAS RAMP.
  • Manual shut-off valve
  • Double solenoid valve
  • High pressure regulator
  • Primary pressure regulator
  • Secondary pressure regulator (Zero pressure regulator)
  • Low pressure switch
  • High pressure switch
  • Valve (tightness) testing system
  • Inlet pressure manometer
  • Outlet pressure manometer
  • Special Start/Stop sequence
  • - ELECTRICAL SYSTEM.
  • Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
  • Battery Switch
  • Adjustable earth leakage protection (time & sensitivity) standard in M12, with thermal magnetic protection
  • Battery charger (standard on gensets with automatic control panels)
  • Heating resistor (standard on sets with automatic control panels)
  • Battery charger alternator with ground connection
  • Starter battery/ies installed (cables and bracket included)
  • Ground connection electrical installation with connection ready for ground spike (not supplied)
  • - EXHAUST SYSTEM.
  • Maximum exhaust temperature: 447 ºC
  • Exhaust Gas Flow: 1,6 kg/s
  • Maximum allowed back pressure: 450 mm H2o
  • - NECESSARY AMOUNT OF AIR.
  • Cooling Air Flow: 20,74 m3/s
  • Alternator fan air flow: 1,961 m3/s
  • - STARTING SYSTEM.
  • Auxiliary Voltage: 12 Vdc
  • - FUEL SYSTEM
  • Fuel Oil Specifications: Biogas

Power


 

Sound level

 dB
 Distance (m)

 
 

dimensions


 
dimensions
Long (A)
0
Width (B)
0
High (C)
0
 

Weight


 
Weight
Weight with liquid in radiator and carter

0
 

Fuel capacity