HYW-1095 T6
1280 kVA Generator set Open Skid
Powered by: YANMAR
Alternator: STAMFORD
Three phase | 60 Hz | Diesel |
- Engine Specifications 1.800 r.p.m.
- Rated Engine Output: 1071,9kW prp ; 1144,9kW standby
- Manufacturer: YANMAR
- Model: AY40L.ET
- Engine Type: 4-stroke diesel
- Injection Type: Direct
- Aspiration Type: Turbocharged and after-cooled
- Number of cylinders and arrangement: 12-V
- Bore and Stroke: 155 x 180 mm
- Displacement: 40,76 L
- Cooling System: Coolant
- Lube Oil Specifications: API CF or CH4, SAE 15W-40
- Compression Ratio: 14,35;1
- Fuel Consumption 100% PRP: 275 l/h
- Fuel Consumption 75 % PRP: 211,3 l/h
- Fuel Consumption 50 % PRP: 149,6 l/h
- Fuel Consumption 25 % PRP: 90,6 l/h
- Lube oil consumption with full load: 0,75
- Total oil capacity including tubes, filters 190 L
- Governor Type Electrical
- Air Filter Type Dry
- Inner diameter exhaust pipe: 205 mm
- Oil temperature sensor
- Low coolant level sensor
- Exhaust gas compensator
- Diesel engine
- 4-stroke cycle
- Water-cooled
- 24V electrical system
- Standard air filter
- Standard fuel filter
- Standard oil filter
- Radiator with pusher fan
- Radiator water level sensor
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Water separator filter (visible level) (Optional)
- Generator: STAMFORD
- Model: HCI634K
- Poles: 4
- Connection type (standard): Star-series
- Mounting type: S-00 21"
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - OPEN SET VERSION.
- Steel chassis
- Emergency stop button
- Oil sump extraction kit
- Anti-vibration shock absorbers
- Chassis with integrated fuel tank
- Fuel level gauge
- Manual oil drain pump
- High mechanical strength
- Fuel tank drain plug
- Fuel transfer pump (Optional)
- Steel industrial silencer -15db(A) attenuation (Optional)
- Steel residential silencer -35db(A) attenuation. (Optional)
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Connection panel wired to the safety protection (open thermal magnetic protection and alarm)
- Maintenance-free and anti-explosion battery
- Battery Switch
- Control panel and emergency stop button
- Battery charger (standard on gensets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- Heating resistor (standard on sets with automatic control panels) (Optional)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 455 ºC
- Exhaust Gas Flow: 256,3 m3/min
- Maximum allowed back pressure: 6 kPa
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 5862 m3/h
- Cooling Air Flow: 26,88 m3/s
- Alternator fan air flow: 1,961 m3/s
- - STARTING SYSTEM.
- Starting power: 8 kW
- Starting power: 10,88 CV
- Recommended battery: 75 x 4 Ah
- Auxiliary Voltage: 24 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: Diesel
- Fuel Tank: 400 L
- - DIMENSIONS.
- Length: 4.450 mm
- Height: 2.313 mm
- Width: 2.100 mm
- Maximum shipping volume: 21,61 m3
- Fuel tank capacity: 400 L
- Autonomy: 2 Hours
Power
kVA
1280
1364
Prime power (6 - 2601)
Stand by (6.5 - 2627)
Stand by (6.5 - 2627)
kW
1024
1091
Prime power (5.8 - 2081)
Stand by (6.2 - 2093)
Stand by (6.2 - 2093)
Sound level
dB
Distance (m)
Distance (m)
dimensions
Long (A)
445
Width (B)
210
High (C)
231,30
Long (A)
175,20
Width (B)
82,68
High (C)
91,06
Weight
Weight with liquid in radiator and carter
0 0
0 0
Fuel capacity
400
105,60