HSY-25 M6

 

HSY-25 M6

20 kVA Generator set Open Skid

Powered by: YANMAR
Alternator: STAMFORD

 

Single phase | 60 Hz | Diesel |

 

 

  • Engine Specifications 1.800 r.p.m.
  • Rated Engine Output: 24,2kW prp ; 28kW standby
  • Manufacturer: YANMAR
  • Model: 4TNV84THSPU
  • Engine Type: 4-stroke diesel
  • Injection Type: Direct
  • Aspiration Type: Turbocharged
  • Number of cylinders and arrangement: 4-L
  • Bore and Stroke: 84 x 90 mm
  • Displacement: 1,995 L
  • Cooling System: Coolant
  • Lube Oil Specifications: SAE 3 class 10W30 / API grade CD,CF
  • Compression Ratio: 18,9
  • Fuel Consumption ESP: 7,67 l/h
  • Fuel Consumption 100% PRP: 6,47 l/h
  • Fuel Consumption 75 % PRP: 4,90 l/h
  • Fuel Consumption 50 % PRP: 3,48 l/h
  • Lube oil consumption with full load: 0,27
  • Total oil capacity: 7,4 L
  • Total coolant capacity: 5,8 L
  • Governor Type Mechanical
  • Air Filter Type Dry
  • Inner diameter exhaust pipe: 34,7 mm
  • Diesel engine
  • 4-stroke cycle
  • Water-cooled
  • 12V electrical system
  • Dry air filter
  • Radiator with pusher fan
  • Mechanical governor
  • Hot parts protection
  • Moving parts protection
  • Generator: STAMFORD
  • Model: S0L2.P1
  • Poles: 4
  • Connection type (standard): Double delta
  • Mounting type: S-4 7,5"
  • Insulation: H class
  • Enclosure (according IEC-34-5): IP23
  • Exciter system: Self-excited, brushless
  • Voltage regulator: A.V.R. (Electronic)
  • Bracket type: Single bearing
  • Coupling system: Flexible disc
  • Coating type: Standard (Vacuum impregnation)
  • - OPEN SET VERSION.
  • Steel chassis
  • Emergency stop button
  • Anti-vibration shock absorbers
  • Chassis with integrated fuel tank
  • Fuel level gauge
  • Steel industrial silencer -15db(A) attenuation
  • Manual oil drain pump (Optional)
  • Fuel transfer pump (Optional)
  • Steel residential silencer -35db(A) attenuation. (Optional)
  • - ELECTRICAL SYSTEM.
  • Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
  • Adjustable earth leakage protection
  • Leakage detector
  • Battery charger (standard on gensets with automatic control panels)
  • Heating resistor (standard on sets with automatic control panels)
  • Battery charger alternator with ground connection
  • Starter battery/ies installed (cables and bracket included)
  • Ground connection electrical installation with connection ready for ground spike (not supplied)
  • Battery Switch (Optional)
  • Optional Battery (Optima) (Optional)
  • - EXHAUST SYSTEM.
  • Maximum exhaust temperature: 560 ºC
  • Exhaust Gas Flow: 6,94 m3/min
  • Maximum allowed back pressure: 1000 mm H2o
  • - NECESSARY AMOUNT OF AIR.
  • Intake air flow: 140,4 m3/h
  • Cooling Air Flow: 0,987 m3/s
  • Alternator fan air flow: 0,126 m3/s
  • - STARTING SYSTEM.
  • Starting power: 1,4 kW
  • Starting power: 1,9 CV
  • Recommended battery: 85 Ah
  • Auxiliary Voltage: 12 Vdc
  • - FUEL SYSTEM
  • Fuel Oil Specifications: Diesel
  • Fuel Tank: 76 L
  • - DIMENSIONS.
  • Length: 1.700 mm
  • Width: 620 mm
  • Fuel tank capacity: 76 L
  • Autonomy: 16 Hours

Power


kVA

20
 
24
Prime power  (6.6 - 200)
Stand by  (7.2 - 220)

kW

20
 
24
Prime power  (6 - 160)
Stand by  (6.5 - 176)
 

Sound level

 dB
 Distance (m)

 
 

dimensions


 
dimensions
Long (A)
170
Width (B)
62
High (C)
0
 

Weight


 
Weight
Weight with liquid in radiator and carter

0
 

Fuel capacity


 
 
76