HSY-10 T6
10.6 kVA Generator set Open Skid
Powered by: YANMAR
Alternator: MECC ALTE
Three phase | 60 Hz | Diesel |
- Engine Specifications 1.800 r.p.m.
- Rated Engine Output: 9,8kW prp ; 11,1kW standby
- Manufacturer: YANMAR
- Model: 3TNV76HSPU
- Engine Type: 4-stroke diesel
- Injection Type: Indirect
- Aspiration Type: Natural
- Number of cylinders and arrangement: 3-L
- Bore and Stroke: 76 x 82 mm
- Displacement: 1,116 L
- Cooling System: Coolant
- Lube Oil Specifications: SAE 3 class 10W30 / API grade CD,CF
- Compression Ratio: 23,5
- Fuel Consumption ESP: 3,767 l/h
- Fuel Consumption 100% PRP: 2,80 l/h
- Fuel Consumption 75 % PRP: 2,21 l/h
- Fuel Consumption 50 % PRP: 1,74 l/h
- Lube oil consumption with full load: 0,27
- Total oil capacity: 3,5 L
- Total coolant capacity: 3,7 L
- Governor Type Mechanical
- Air Filter Type Dry
- Inner diameter exhaust pipe: 40 mm
- Diesel engine
- 4-stroke cycle
- Water-cooled
- 12V electrical system
- Dry air filter
- Radiator with pusher fan
- Mechanical governor
- Hot parts protection
- Moving parts protection
- Generator: MECC ALTE
- Model: ECP28.2VS4C
- Poles: 4
- Connection type (standard): Star-series
- Mounting type: S-5 7"1/2
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - OPEN SET VERSION.
- Steel chassis
- Emergency stop button
- Anti-vibration shock absorbers
- Chassis with integrated fuel tank
- Fuel level gauge
- Steel industrial silencer -15db(A) attenuation
- Manual oil drain pump (Optional)
- Fuel transfer pump (Optional)
- Steel residential silencer -35db(A) attenuation. (Optional)
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Adjustable earth leakage protection
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- Battery Switch (Optional)
- Optional Battery (Optima) (Optional)
- Leakage detector (Optional)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 565 ºC
- Exhaust Gas Flow: 3,24 m3/min
- Maximum allowed back pressure: 1000 mm H2o
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 54,216 m3/h
- Cooling Air Flow: 0,693 m3/s
- Alternator fan air flow: 0,13 m3/s
- - STARTING SYSTEM.
- Starting power: 1,1 kW
- Starting power: 1,5 CV
- Recommended battery: 66 Ah
- Auxiliary Voltage: 12 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: Diesel
- Fuel Tank: 60 L
- - DIMENSIONS.
- Length: 1.450 mm
- Width: 620 mm
- Fuel tank capacity: 60 L
- Autonomy: 27 Hours
Power
kVA
10.6
12
Prime power (6.6 - 200)
Stand by (7.2 - 220)
Stand by (7.2 - 220)
kW
8.5
9.6
Prime power (6 - 160)
Stand by (6.5 - 176)
Stand by (6.5 - 176)
Sound level
dB
Distance (m)
Distance (m)
dimensions
Long (A)
145
Width (B)
62
High (C)
0
Long (A)
57,09
Width (B)
24,41
High (C)
0
Weight
Weight with liquid in radiator and carter
0 0
0 0
Fuel capacity
60
15,84